  • Boiler Error Codes - boilerPRO

    So your boiler is flashing and its showing a random set of numbers and letters? This is an error code, and each error code is specific to the error.Get Price

  • Boiler Fault Codes - Mr Engineers

    May 03, 2020 · Mr Engineers Our team are certified & licensed Gas Safe Engineers ready to provide you with all types of landlord safety certificates in London and the M25 area for domestic purposes.. At Mr Engineers, we treat each customer with utmost respect that they really deserve. Our dedicated staff provides great customer service to ensure that you have a memorable …Get Price

  • glowworm flexicom 30cx boiler - over pressure & drip

    Aug 28, 2019 · Hi, after some help with a flexicom 30 CX - 9 Years old. Pressure slowly creeps up toward 3 bar, followed by a very slow drip. Plumber has been out & done the follwing: Represurised expansion vessel. Relpaced plate heat exchanger. confirmed both filling loop valves are passing water. Plumber now out of ideas - suggests Gloworm expensive call out.Get Price

  • Glow-worm Boiler Fault Codes and Manuals - Gas Call

    Glow-worm Boiler Fault Codes and Manuals Listed below are Glow-worm boiler fault codes and Glow-worm boiler Manuals. Fault Code Cause of Problem F.00 Fault: Flow temperature sensor F.00 Fault: Flow temperature sensor F.10 Short circuit: …Get Price

  • 2021 Glow Worm Boiler Error & Fault Codes Explained

    If your Glow Worm Compact E Range Boiler is displaying any of the following codes, or a combination of the codes below we can help you to identify and resolve your E Range boiler problems. Fault Code Possible CauseGet Price

  • Glow-Worm Xtramax HE Boiler Range Error Codes - Mr Engineers

    May 03, 2015 · Ignition fault: F5: Overheat Fault: F6: Central heating flow thermistor: F7: Domestic hot water thermistor: F8: Tank thermistor: F9: Water pressure sensor fault (please contact GW technical department for further information) F10: Central return flow thermistor: F11: Main board connection fault: F12: User interface connection fault: F13: PCB memory or sensing fault: F14Get Price

  • Glowworm Xtramax HE exploded views and parts list

    Glowworm Xtramax Range; Glowworm Xtrafast Range; Glowworm 24-35 CI Range; Glowworm Easicom Range; Myson Boiler Spares Finder; Potterton; Powermax; Protherm Boiler Spares Finder; Radiant; 90 FAULT CODES. Find Your Local Store. Register Your Account. Manage Your Online Account Get Price

  • Worcester Boiler Error Codes [Full 2022 List] - Boiler Central

    Worcester Bosch offers some of the most reliable boilers on the market but they are not immune to the perils of use. Occasionally, you will run into a problem with your boiler, and when this happens, you will need to know how best to handle it.Get Price

  • F11, F12, F13 & F14 Glow-worm Fault Error Code Problems

    Apr 27, 2019 · Glow-worm F11, F12, F13 & F14 fault code failure problems occur unfortunately, on a small number of 24, 30 & 38, CXI, HXI & SXI combi or system boilers. This is typically when they get to about 10 years old or older. At Glowcare (being Glow-worm's service agent for the North West of England since 1992), we do come across our fair share of F11 Get Price

  • 2021 Glow Worm Boiler Error & Fault Codes Explained

    If your Glow Worm Compact E Range Boiler is displaying any of the following codes, or a combination of the codes below we can help you to identify and resolve your E Range boiler problems. Fault Code Possible CauseGet Price

  • Worcester Boiler Error Codes [Full 2022 List] - Boiler Central

    Worcester Bosch offers some of the most reliable boilers on the market but they are not immune to the perils of use. Occasionally, you will run into a problem with your boiler, and when this happens, you will need to know how best to handle it.Get Price

  • miura boiler fault codes - giaiphapsuckhoe.com

    Nov 22, 2021 · miura boiler fault codes. Giải Pháp Sức Khỏe là Trang thông tin chính thức của Cục Y tế dự phòng – Bộ Y tế, cung cấp đầy đủ các thông tin chính thống, kiến thức và hàng loạt các tiện ích để phục vụ người dân chủ động chăm sóc sức khỏe bản thân và gia đình theo Chương trình Sức khỏe Việt Nam, vì một Get Price

  • Glow-Worm Boiler Fault Codes | Team Boiler

    91 rows · Glow-worm Error Codes F1, F4, F28 or F29. If you are seeing the error codes F1, F4 …Get Price

  • Error codes for boilers — Professional Heating Services Ltd

    Overheat Fault All Boilers F6 Central heating flow thermistor All Boilers F7: Domestic hot water thermistor All Boilers F8: Tank thermistor fault sxi / si / ci (plus) range / Xtramax HE F9: Water pressure sensor fault (please contact GW technical department for further information) All boilers F10: Central return flow thermistorGet Price

  • Glowworm - FREE BOILER MANUALS

    View Glowworm User Manuals View Glowworm Fault Codes. Glowworm Glow worm Capricorn 246 boiler; Glow worm Compact 100e; Glow worm Easicom 24; Glow worm Easicom 28; Glow worm Xtrafast 120; Glow worm Xtramax; GC No.47 047 18; GC No.47 047 19; GC No.41 047 61; GC No.47 047 23 ;Get Price

  • F5 Fault Code Glow Worm Boiler | What does this mean & can

    What will the gas safe engineer do when fixing a F5 fault code on a Glow Worm Boiler. As explained in the fault manual all the gas safe registered engineer will do is as listed below. Turn off boiler for a minute or so. Take off casing. Press the overheat stat button in (location depends on make of boiler).Get Price

  • Glow Worm Boilers | Repair Network

    Glow Worm Boilers. Glow Worm boilers are available as combi, system and regular models. For more than 80 years, Glow Worm has been leading the heating industry in the UK. It started in 1934 in Derbyshire when the first boiler was produced. During the decades since, Glow Worm has been producing durable and long-lasting heating solutions.Get Price

  • Does anyone know the error code FL on Ideal Isar HE24 boiler

    May 29, 2013 · if it carries on doing it it could be a number of things none of which is a diy job, because a number of things need to be tested. not one of the cheapest boilers to fix & also one of the worst boilers made, i don't normally say this but i would highly recommend signing up to one of the monthly service schemes while it is still working or it will cost you a good few quid in …Get Price

  • Glowworm 30 hxi F3 fault | DIYnot Forums

    Feb 21, 2009 · miniman. I have a glow worm 30 hxi boiler. . The gasket on the heat exchanger door has obviously deteriorated over a period of time, unfortunately buckling the heat exchanger door. I have aquired a new door and gasket etc and fitted without any problems. The boiler is failing to start however giving an F3 fault.Get Price

  • Maintenance and Service - upperplumbers.co.uk

    Glowworm Xtramax HE. Combination boiler Glowworm Xtramax HE with a hot water storage cylinder discharges a lot of water from the Temperature and Pressure Relief Valve (T&PRV). After I turned the power on and put a hot water demand approximately after 10 seconds when a secondary, hot water pump start working but all hot water taps are closed and Get Price

  • The Glow-Worm Boiler Fault Code F14 Error Common Q & A

    If you're having problems with your Glow-Worm boiler, they'll be a fault code displayed on the control panel (F14 in this case). This helps your boiler engineer to determine the most likely cause of the fault. The F14 fault code relates to a problem with the gas valve and electronics that control its operation.Get Price

  • How to Reset a Boiler: Get Your Boiler Firing Up Again

    A boiler needs to be reset after a fault has been fixed. Find out Common Ideal Boiler Problems and Repair Advice. How to reset a Vaillant boiler. The reset button on Vaillant ecoTEC boilers has an icon of a flame with a cross through it. Their ecoFIT Pure range of boilers also uses this same icon but it's next to the reset button rather than Get Price

  • Ask Glow-worm

    The Glow-worm Xtramax HE is a High efficiency boiler that is not currently in production. Please check the frequently answered questions below for any help you may need. You can also click here to visit the appliance homepage.Get Price

  • Fault Finding Codes | Boilers | Glow-worm

    Energy Boiler Range Fault Codes. Fault finding codes for the Energy boiler range.Get Price

  • Glowworm S1007000 Filling Cock - Ultracom 2 24cxi

    xtramax he Previous Part Codes: 1007000, 801907, S10070, 2000801907 Glowworm Filling loops can be internal or external but both work in the same manner, should the pressure in your Glowworm boiler be too low or keeps dropping, repressurising your boiler and central heating system is extremely easy, First of all, identify the pressure gauge on Get Price

  • miura boiler fault codes - msprojectpodcast.com

    Feb 16, 2021 · The F75 Fault code on the modern range of Vaillant Boilers (including the EcoTec Plus, Ecotec Pro, Ecomax and EcoFit) and the F9 / F75 Fault code on modern Glowworm boilers (including the CXI, SXI, Flexicom, Energy and Betacom) is probably the …Get Price

  • Fault Finding Codes - Glow-worm - Replacement Boiler

    Codes Description; F1: Ignition fault : F2: Fan : F3: Fan : F4: Ignition fault : F5: Overheat Get Price

  • Ask Glow-worm

    Click here to access the fault codes. Technical Specification The main feature of the Xtramax HE is the built-in 42-litre shift load store that enables the Xtramax HE to produce up to 200 litres of usable domestic hot water, much more than a conventional combination boiler.Get Price

  • Glow Worm Fault Codes – MyBoiler.com

    Xtramax HE: F24: Link: Cental heating return temperature > 90 degrees: sxi: F24: Link: Cental heating return temperature > 90 degrees: hxi: F24: Link: Central heating return temperature > 90 degrees: flexicom cx: F24: Link: Central heating return temperature > 90 degrees: cxi: F25: Link: Maximum temperature rise slope: Xtramax HE: F25: Link: Circulation fault: Ultrapower sxi: F25: …Get Price

  • Error Codes Archives - Boiler Fault Finder

    Boiler Error Codes. THE Heating Engineers Boiler Technical Resource. HomeGet Price

  • The Glow-Worm Boiler Fault Code F3 Error Common Q & A

    However, in the case of the F3 fault code on Glow-Worm boilers, it's likely the lock out occurs, to stop the boiler from being dangerous. The F3 code relates to a fan fault. The fan can't reach the correct speed for the boiler to ignite.Get Price

  • Glow-worm Boiler Problems, Repair Advice & How to Fix

    Glow-worm boilers come with 2-7 years of warranty as standard but some models are eligible for up to 15 years of warranty through Glow-worm's club energy installers. Find out more with our guide to Glow-worm warranties. Keeping the warranty valid means arranging for an annual service of your Glow-worm boiler that will also ensure the safe and Get Price

  • Fault Finding Codes - Glow-worm - Replacement Boiler

    F13. PCB memory or sensing fault. F14. Gas valve control defective. F15. E-bus voltage failure. F22. Low water pressure or ignition temperature rise too slow. F25.Get Price

  • Glow-Worm Boiler Error Codes / Fault Codes | WarmZilla

    27 rows · Jul 14, 2021 · Glow-worm Error Codes F1, F4, F28 or F29 If you are seeing the error codes F1, F4 F28, or Get Price

  • Glow-worm Boiler Fault Codes and Manuals Compact

    Glow-worm Boiler Fault Codes and Manuals Listed below are Glow-worm boiler fault codes and Glow-worm boiler Manuals. Fault Code Cause of Problem F.00 Fault: Flow temperature sensor F.00 Fault: Flow temperature sensor F.10 Short circuit: …Get Price

  • Boiler Error Codes - boilerPRO

    So your boiler is flashing and its showing a random set of numbers and letters? This is an error code, and each error code is specific to the error.Get Price

  • Glow-Worm Xtramax HE Boiler Range Error Codes

    Boiler Fault Finder Ltd Pine Villa Wolborough Close, Newton Abbot Devon TQ12 1HR . Email: [email protected] Web: boilerfaultfinder.com. Boiler Fault Finder Ltd. Registered in England Number: 8610232Get Price

  • 6 Causes of Vaillant F75 and Glowworm F9 fault codes

    The F75 Fault code on the modern range of Vaillant Boilers (including the EcoTec Plus, Ecotec Pro, Ecomax and EcoFit) and the F9 / F75 Fault code on modern Glowworm boilers (including the CXI, SXI, Flexicom, Energy and Betacom) is probably the most common fault that we attend. It is usually a fairly simple fix,Get Price

  • Glow-worm Boiler Error Codes - Mr Engineers

    May 03, 2015 · Xtramax HE Range: F24: Cental heating return temperature > 90 degrees: Xtramax HE Range: Get Price

  • Glow worm xtramax he manual | Joan Daniels's Ownd

    Dec 11, 2021 · Boiler Glow-worm Xtramax HE Instructions For Use Manual High efficiency condensing boilers (12 pages) Boiler Glow-worm Glow-worm Instructions For Use Manual. Glow Worm Flexicom Sx User Manual Posted on 12/6/ by admin Listed below are the common Glowworm fault codes as described by the boiler manufacturer along with a possible cause. …Get Price

  • Fault Codes Request – MyBoiler.com

    Best Boilers 2017; Choosing a New Boiler; Open Therm & Modulating Boilers. OpenTherm Capable Boilers; OpenTherm Controls; Modulating Boilers & Smart Controls; Vaillant Boiler and OpenTherm; Worcester Bosch and OpenTherm; Flow Temperature and Power Output relationship; Fault Codes. Glow Worm Fault Codes; Intergas Fault Codes; Potterton Fault Get Price

  • Fault Finding Codes - Glow-worm - Replacement Boiler

    F13. PCB memory or sensing fault. F14. Gas valve control defective. F15. E-bus voltage failure. F22. Low water pressure or ignition temperature rise too slow. F25.Get Price

  • Vokera Fault Codes – MyBoiler.com

    NB Some fault codes are only applicable to a specific range of boilers only. Primary flow thermistor fault Ð temperature of water is too high. Return thermistor fault Ð water temperature too high. Flue thermistor or ßue thermistor counter …Get Price

  • Glowworm Flexicom 24CX, 30CX, 35CX - Boiler Spares

    Glow-Worm. Glowworm Flexicom Range. Glowworm Flexicom 24CX, 30CX, 35CX; Need some help? Call our friendly UK based support team on. Glowworm Xtramax HE. Common Spares. Diverter Valve 0020014168. Part number S016025 Manf …Get Price

  • Glowworm Flexicom 12hx error codes. | PlumbersForums.net

    Aug 03, 2021 · Jul 31, 2021. #2. You need to find the filling loop. Look for two valves connected by a silver braided hose. Open both valves for 5 secs and listen for the water going in. Then shut valves and check on boiler. You may need to reset boiler. I'd look for the filling loop near your hot water cylinder if it's not near the boiler.Get Price

  • British Gas - 330 - FREE BOILER MANUALS

    High Efficiency Condensing Boiler 0020008877-04 08.06 12373 G.C. No. 41-047-75 British Gas 330 Customer Care Line Tel: 0845 600 5100. 0020008877-04 2 MAINTENANCE of the boiler. It is normal and not a fault indication. Cleaning The boiler casing can be cleaned using a mild liquid detergent with a damp cloth, then a dry cloth to polish. Get Price

  • Glow-worm Fault Codes - FREE BOILER MANUALS

    91 rows · Xtramax HE Range: F24: Cental heating return temperature > 90 degrees: Xtramax HE …Get Price

  • 6 Causes of Vaillant F75 and Glowworm F9 fault codes

    The F75 Fault code on the modern range of Vaillant Boilers (including the EcoTec Plus, Ecotec Pro, Ecomax and EcoFit) and the F9 / F75 Fault code on modern Glowworm boilers (including the CXI, SXI, Flexicom, Energy and Betacom) is probably the most common fault that we attend. It is usually a fairly simple fix,Get Price

  • Glow Worm Archives - Boiler Fault Finder

    Boiler Fault Finder Ltd Pine Villa Wolborough Close, Newton Abbot Devon TQ12 1HR . Email: [email protected] Web: boilerfaultfinder.com. Boiler Fault Finder Ltd. Registered in England Number: 8610232Get Price